跳到正文
arXiv (AI + Vision + Imaging)· Sezgin Er, Utku Turkbey, Alperen Gur, Omer Faruk Durugol, Suprosanna Shit, Murong Xu, Julia Wolleb, Jiayi Wang, Xiaoliang Wang, Hadrien Reynaud, Teodora Spasojevic, Dong Yang, Andriy Myronenko, Pengfei Guo, Yufan He, Can Zhao, Marc Edgar, Andreas Maier, Michael Moor, Mehmet Kemal Ozdemir, Daguang Xu, Bernhard Kainz, Bjoern Menze, Ibrahim Ethem Hamamci·· 1 天前精选AI 评分58

FORA:可识别1028个放射学概念并生成报告的通用CT模型

Reliable and grounded reporting of any computed tomography scan with FORA

AI 导读

研究团队提出通用CT模型FORA,可识别并空间定位1028个分层组织的放射学概念,覆盖队列中28种CT协议并生成报告。模型基于304,962例常规CT检查及其配套报告训练,无需人工标注病灶即可学习定位异常。在36,619例留出CT检查上,放射学概念识别的macro AUROC为0.918,比18个现有CT模型中最强者高0.21,并在三个公开基准上排名第一。

推荐理由

FORA 用常规报告监督实现跨 28 种 CT 协议的异常识别与空间定位,读者可据此了解通用 CT 基础模型的技术路线。

正文 · 原文

arXiv:2611.32823v1 Announce Type: new Abstract: Artificial intelligence systems for computed tomography (CT) remain largely restricted to specific anatomical regions, examination types or predefined abnormalities, limiting their ability to provide comprehensive and spatially grounded interpretations. Here we present FORA, a general-purpose CT model that recognizes and spatially localizes 1,028 hierarchically organized radiological concepts and generates reports across the 28 CT protocols represented in our cohort. Trained on 304,962 routine CT examinations supervised by their accompanying reports, FORA learns to localize abnormalities without manually annotated lesions. Its architecture combines multiple-instance learning with an interpretable concept bottleneck that connects spatial evidence, radiological findings and report generation. We first developed and benchmarked the architecture on chest radiographs, achieving state-of-the-art performance, before training a separate model on three-dimensional CT examinations. On 36,619 held-out CT examinations, FORA achieved a macro area under the receiver operating characteristic curve (AUROC) of 0.918 for radiological concept recognition, exceeding the strongest of 18 existing CT models by 0.21. FORA also ranked first on three public benchmarks, outperforming Merlin on its own test set without training on that institution's data (AUROC 0.907 versus 0.826). On independent localization benchmarks for pulmonary emboli, renal masses and rib fractures, FORA's strongest spatial evidence fell within annotated lesions at rates up to 348 times greater than chance. FORA achieved more than threefold higher macro-averaged finding recall than the strongest existing report generator. These results show that a single model can combine broad abnormality recognition, spatial localization and report generation across 12 CT examination types, using routine reports without lesion-level supervision.

来源:arXiv (AI + Vision + Imaging) · arxiv.org