界面注入声子谱决定热反射法测得的表观热导率
Apparent thermal conductivity governed by interface-injected phonon spectra
研究按模式解析半无限Si的表面温度响应,发现短声子平均自由程加权的注入会抬高表面温度,长平均自由程加权则降低。对Al(70 nm)/Si结构,合成TDTR相位信号的傅里叶拟合给出Si的κ_app约93至360 W/(m K),且κ_app与透射声子的热流加权平均自由程相关。热反射法测得的表观热导率不仅反映衬底热学性质,也反映跨换能器界面注入的声子谱。
Thermoreflectance techniques such as time- and frequency-domain thermoreflectance (TDTR and FDTR) are widely used to measure the thermal conductivity of bulk materials, thin films, and interfaces. When phonon mean free paths $Λ_ω$ become comparable to the thermal penetration depth, a Fourier analysis yields an apparent thermal conductivity $κ_{\rm app}$ that deviates from the bulk value $κ_{\rm bulk}$. Recent studies have highlighted the role of the phonon spectrum injected through the transducer interface, which is generally out of equilibrium owing to frequency-dependent transmission, and have shown that accounting for this nonequilibrium distribution can yield $κ_{\rm app}>κ_{\rm bulk}$, unlike conventional suppression-function analyses that predict only $κ_{\rm app}\leqκ_{\rm bulk}$. However, the spectral characteristics governing whether $κ_{\rm app}$ is enhanced or reduced remain unclear. Here, we resolve the surface-temperature response of semi-infinite Si mode by mode and show that short-$Λ_ω$-weighted injection raises the surface temperature, whereas long-$Λ_ω$-weighted injection lowers it. This behavior is governed by how deep the injected phonons travel before thermalizing with the lattice, which is set by their mean free paths, and by how effectively the substrate conducts the injected energy away, which is limited by its long-mean-free-path phonons. For an Al (70 nm)/Si structure, Fourier fits of synthetic TDTR phase signals give $κ_{\rm app}$ of Si from about 93 to 360 W/(m K) for different interfacial transmission spectra, and $κ_{\rm app}$ correlates with the heat-flux-weighted $Λ_ω$ of the transmitted phonons. Thus, $κ_{\rm app}$ from thermoreflectance reflects not only the substrate thermal properties but also the phonon spectrum injected across the transducer interface.
来源:arXiv (Materials + Coatings) · arxiv.org