基于李群理论补全DH、Hayati、CPC与POE模型间解析转换方案,提升机械臂标定精度
Completing analytical conversion scheme among DH, Hayati, CPC and POE models for manipulator calibration
研究基于李群理论构建了POE-HAY与HAY-CPC模型间的直接解析转换算法,填补了此前只能通过POE-DH-HAY顺序组合转换的空白。在RRRP SCARA与RRHHHH Puma 560上的对比表明直接转换优于顺序方案,并在ABB IRB 1600配合API Radian EMSD3激光跟踪仪的开环运动学标定实验中验证了合理选型加完整转换方案可直接提升标定精度。
arXiv:2611.31054v1 Announce Type: new Abstract: Building on Mooring's decomposition of the calibration procedure into four stages - modeling, measurement, identification, and correction - this paper investigates the role of analytical kinematic model conversion algorithms within the calibration framework and their potential to improve calibration performance. Four prominent and widely cited kinematic models: Denavit-Hartenberg (DH), Hayati (HAY), Complete and Parametrically Continuous (CPC), and Product of Exponentials (POE), - are considered. A systematic analysis of the existing conversion relationships reveals that, although most conversions among these models have already been established in the literature, a direct analytical conversion between POE and HAY, and CPC and HAY remains unavailable. Relying instead on a sequential combination of the existing POE-DH and DH-HAY conversions, for example, introduces several limitations. To address this gap, we develop a constructive analytical conversion between POE-HAY and HAY-CPC models based on Lie group theory, formally established through a set of lemmas and propositions. The proposed algorithms are illustrated using an RRRP SCARA robot and an RRHHHH Puma 560 manipulator. The direct POE-HAY conversion is compared with the sequential POE-DH-HAY approach, as well as HAY-CPC in terms of several relevant criteria, demonstrating the advantages of the proposed solution. Finally, we demonstrate the practical significance of the completed analytical conversion framework in an open-loop kinematic calibration experiment on an ABB IRB 1600 manipulator, using an API Radian EMSD3 Laser Tracker for measurements. The experimental results demonstrate that proper model selection combined with completed analytical conversion scheme directly improves calibration accuracy.
来源:arXiv (Robotics + Hardware + Signal) · arxiv.org