arXiv (AI + Vision + Imaging)· Johannes B. Thalhammer, Kacper Og\'orek, Tina Dorosti, Sebastian Peterhansl, Daniel Frey, Zijin Huang, Theresa Hiu, Tobias Lasser, Daniela Pfeiffer, Franz Pfeiffer, Florian Schaff·· 4 小时前AI 评分22

扩散自编码器实现类条件合成胸部CT:隐私感知且具诊断价值

Diagnostically Meaningful, Privacy-aware Synthetic Chest CT via Class-Conditional Latent Sampling in Diffusion Autoencoders

AI 导读

研究团队开发了基于扩散自编码器的类条件合成胸部CT生成框架,在RSNA 2020肺栓塞数据集上训练,通过类特定核密度估计采样潜在表示并引入潜在空间距离过滤,拒绝最近邻距离低于阈值的样本。合成数据训练的ResNet-50分类器AUC为0.862,接近真实数据训练的0.872,差异虽显著但绝对值很小。对38,000张合成切片的最近邻复制检测未发现真实训练图像的直接复制。

正文 · 原文

arXiv:2611.33234v1 Announce Type: new Abstract: Large, well-annotated datasets are essential for developing medical artificial intelligence models, yet data sharing is often restricted by privacy regulations. Synthetic images may help address this limitation if they preserve diagnostic information while reducing the risk of reproducing patient data. We developed a diffusion autoencoder-based framework for class-conditional synthetic chest CT generation that incorporates latent-space distance filtering to reduce the likelihood of regenerating training samples. A diffusion autoencoder was trained on the public RSNA 2020 Pulmonary Embolism (PE) dataset. PE-positive and PE-negative images were synthesized by sampling latent representations from class-specific kernel density estimates. Samples with a nearest-neighbor latent-space distance below a predefined threshold were rejected. To assess diagnostic utility, ResNet-50 classifiers were trained across 10 independent runs using real, synthetic, or mixed real-synthetic datasets. Performance was evaluated on a held-out real test set using the area under the receiver operating characteristic curve (AUC), with DeLong 95% confidence intervals (CIs). Models trained on synthetic data achieved an AUC of 0.862 (95% CI, 0.851-0.874), only slightly lower than models trained on real data (AUC = 0.872, 95% CI, 0.861-0.883) and mixed real-synthetic data (AUC = 0.865, 95% CI, 0.855-0.876). These differences were statistically significant (p < 0.05) but small in absolute terms. A nearest-neighbor copy-detection analysis of 38,000 synthetic slices found no direct copies of real training images. These findings indicate that the synthetic CT images preserve diagnostically meaningful information for image-level PE classification while incorporating measures intended to enhance privacy awareness and reduce similarity to real patient data.

来源:arXiv (AI + Vision + Imaging) · arxiv.org