ALPS II 双激光外差探测系统:非共振本振激光将 SNR 提升约 35 倍
Two-Laser Heterodyne Detection System for ALPS II
ALPS II 采用双激光外差探测方案,以非共振激光作为本振(LO)替代原共振设计,避免本振离模分量噪声主导噪声预算。噪声模型预测该改动可将实验 SNR 提升约 35 倍,并通过向再生腔注入弱信号、对比两种配置灵敏度的实验得到验证。
arXiv:2610.03376v3 Announce Type: replace Abstract: The Any Light Particle Search II employs a highly sensitive heterodyne detection system to measure an ultra-weak electromagnetic field that is reconverted from axions inside a regeneration cavity (RC). The initial design of the heterodyne system utilized a local oscillator laser (LO) that was resonant with the RC to form an interference beatnote with the weak signal field exiting the cavity. A weakness of this design is that it is possible for the out-of-mode field component of the LO to be larger than the in-mode component, allowing its noise to dominate the optical component of the noise budget and reducing the SNR of the experiment. This problem can be addressed by introducing a second, non-resonant laser as the LO. Since the in-mode light of this laser does not couple to the cavity, significantly more of its power is reflected than when the LO is resonant. We present a model for the measurement noise that predicts these design changes increase the SNR by a factor of roughly 35. This model was then confirmed experimentally by injecting a weak signal to the RC and examining the difference in the sensitivity of the detection system in each of these configurations.
来源:arXiv (Optics + Display + Materials) · arxiv.org