arXiv (Optics + Display + Materials)· Julianna Winnik (Institute of Micromechanics and Photonics, Warsaw University of Technology, Warsaw, Poland), Piotr Zda\'nkowski (Institute of Micromechanics and Photonics, Warsaw University of Technology, Warsaw, Poland), Konrad Kosuge (Institute of Micromechanics and Photonics, Warsaw University of Technology, Warsaw, Poland), Aleksandra Parys (Institute of Micromechanics and Photonics, Warsaw University of Technology, Warsaw, Poland), Marzena Stefaniuk (Laboratory of Neurobiology, BRAINCITY, Nencki Institute of Experimental Biology, Polish Academy of Sciences, Warsaw, Poland), Junwei Min (State Key Laboratory of Ultrafast Optical Science and Technology, Xi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an, China), Baoli Yao (State Key Laboratory of Ultrafast Optical Science and Technology, Xi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an, China, University of Chinese Academy of Sciences, Beijing, China), Maciej Trusiak (Institute of Micromechanics and Photonics, Warsaw University of Technology, Warsaw, Poland)·· 4 小时前AI 评分36

深度学习辅助振幅估计的梯度光学衍射层析成像(AI-GODT)

Gradient Optical Diffraction Tomography Using Deep Learning-Assisted Amplitude Estimation

AI 导读

研究提出振幅信息梯度光学衍射层析成像(AI-GODT),用基于ResNet的物理信息监督深度学习,从横向剪切干涉的条纹调制数据中估计原GODT中缺失的振幅梯度。数值仿真与对标准测试物体及原代神经元细胞培养的实验测量验证了该网络可泛化至多样样品,将恢复的振幅梯度纳入重建流程后,三维重建质量提升,尤其改善离焦区域。软件与数据集已公开。

正文 · 原文

arXiv:2611.34059v1 Announce Type: new Abstract: Gradient Optical Diffraction Tomography (GODT) enables the non-invasive reconstruction of a spatial derivative of the 3D sample's refractive index distribution, providing enhanced sensitivity to subtle refractive index variations through gradient-based contrast. Implemented using lateral shearing interferometry (LSI), GODT benefits from a common-path architecture that provides environmental stability and high signal-to-noise ratio measurements. Unlike conventional optical diffraction tomography (ODT), which requires numerical integration of LSI-derived phase gradients to recover the object phase, GODT enables direct tomographic reconstruction from the LSI data. Notably, GODT requires derivatives of both the phase and amplitude of the object fields as input. While the phase derivative can be readily extracted from LSI data, the amplitude gradient cannot be directly retrieved. Thus, in the original GODT formulation, the amplitude gradient was assumed to be negligible, limiting the accuracy of the resulting 3D reconstruction. In this work, we introduce amplitude-informed GODT (AI-GODT), which employs physics-informed supervised deep learning to estimate the missing amplitude gradient based on accessible LSI data, specifically the fringe modulation. The proposed approach, applying a ResNet architecture and training on computer-generated data, is validated through numerical simulation and experimental measurements of both a well-characterized test object and primary neuronal cell culture, demonstrating the network's ability to generalize to diverse samples. We show that incorporation of the recovered amplitude gradient into the GODT reconstruction pipeline improves the 3D reconstruction quality, especially in its out-of-focus regions. The software and datasets are openly available to facilitate reproducibility and further development.

来源:arXiv (Optics + Display + Materials) · arxiv.org