基于深度集成校准选择性预测的甲状腺结节超声分类在数据集偏移下的表现

Calibrated selective prediction using deep ensembles for thyroid nodule ultrasound classification under dataset shift

AI 导读

研究构建ConvNeXt-Tiny五成员深度集成框架,在TN5000上实现AUC-ROC 0.9377、校准误差0.0138,按互信息策略对8.86%图像给出免穿刺建议。该集成迁移至TN3K后AUC-ROC降至0.7870、校准误差升至0.1899,显示数据集偏移下可迁移性有限,临床使用前需多中心验证与站点特异性重校准。

正文 · 原文

arXiv:2607.12075v3 Announce Type: replace Abstract: Background: Deep learning can classify thyroid nodules on ultrasound, but discrimination alone does not establish clinical reliability. We developed a calibrated deep-ensemble framework with uncertainty-aware selective prediction and conservative image-based triage. Methods: Nested five-fold cross-validation with three-fold inner architecture selection chose ConvNeXt-Tiny with a squeeze-and-excitation block, used to build a deterministic five-member ensemble. Training, early-stopping, calibration, and threshold subsets were separated within each fold; outer-test data remained isolated. Mutual information (MI), predictive variance, and maximum-softmax-probability (MSP) uncertainty were compared by risk-coverage and triage analyses, and predictive values across assumed malignancy prevalences of 5%-70%. The frozen TN5000 ensemble was applied to TN3K without recalibration. Results: On TN5000, pooled out-of-fold AUC-ROC was 0.9377, average precision 0.9708, expected calibration error 0.0138, and Brier score 0.0827. Under the primary MI-guided policy, 8.86% of images received a No-FNA suggestion, 60.00% an FNA recommendation, and 31.14% radiologist review; of 3574 malignant images, 14 (0.39%) received No-FNA and 708 (19.81%) review. Predictive variance and MSP ranked errors better than MI (AURC, AUGRC); no measure optimized all triage outcomes. Across prevalences of 5%-70%, NPV ranged 99.95%-97.93% and PPV 29.28%-94.75%. On TN3K, AUC-ROC was 0.7870, average precision 0.7254, expected calibration error 0.1899, and radiologist-review rate 83.7%. Conclusion: The ensemble showed strong internal discrimination and calibration, but performance deteriorated substantially on TN3K, indicating limited transportability under dataset shift. Multicentre validation, site-specific recalibration, threshold validation, and prospective evaluation are needed before clinical use.

来源:arXiv (AI + Vision + Imaging) · arxiv.org