跳到正文
arXiv (AI + Vision + Imaging)· Siyuan Hou, Shuting Yang, Zengrui Jin, Liyu Cheng, Siyin Wang, Yunhan Shi, Xueyan Li, Rong Hu, Yuhong Lin, Qiyu Chen, Yanru Li, Ji Wu, Bowen Zhou, Mangsuo Zhao, Wen Xu, Chao Zhang·· 8 天前AI 评分18

听觉AI辅助喉镜检查前喉部疾病分类:一项配对阅片者研究

Clinician Assessment of Laryngeal Disease with Auditory AI before Laryngoscopy: A Paired Reader Study

AI 导读

一项配对阅片者研究显示,32名耳鼻喉科医生在查看听觉大语言模型生成的患者评估卡后,喉镜检查前分类准确率从49.8%升至56.8%,提升7.0个百分点。该模型基于语音录音、患者信息和声学指标生成暂定分类、音质评分与恶性病变警报,暂定分类在留出测试集和时间验证集中准确率分别为72%和67%。AI辅助复核后,癌前或恶性病变检出敏感度从53.9%提高到75.0%。

正文 · 原文

arXiv:2611.20050v1 Announce Type: cross Abstract: Background: Before laryngoscopy, clinicians assess the likely cause of hoarseness and whether to suspect a precancerous or malignant lesion. Whether voice-based artificial intelligence (AI) supports pre-laryngoscopic categorization is unknown. Methods: We developed an auditory large language model that generates a patient-level assessment card (provisional category, voice-quality ratings, and rationale) and a prespecified malignancy alert from voice recordings, patient information, and acoustic measures obtained before laryngoscopy at one center. We evaluated both in a held-out test set and a later cohort. In a sequential reader study, 32 otolaryngology clinicians categorized held-out cases without AI and, 1 to 2 weeks later, reviewed their initial categories with the card (without the alert). Results: Across 800 paired assessments, reader accuracy was 49.8% before and 56.8% after review (difference, 7.0 percentage points; 95% CI, 1.7 to 13.5; P < 0.001); 99 categories changed from incorrect to correct and 43 from correct to incorrect (ratio, 2.30; 95% CI, 1.22 to 5.31). Accuracy rose 14.7 points when the model was correct and fell 8.7 when incorrect. Provisional-category accuracy was 72% in held-out testing and 67% in temporal validation. The malignancy alert flagged 85.7% and 86.8% of precancerous or malignant lesions. Sensitivity for precancerous or malignant lesions increased from 53.9% to 75.0% after AI-assisted review (difference, 21.1 percentage points; 95% CI, 4.3 to 42.0). Conclusions: In this single-center study, clinicians' pre-laryngoscopic categorization accuracy was higher after reviewing the AI assessment card, although the sequential design cannot fully separate AI assistance from reassessment; gains depended on model correctness without clearly selective adoption. Randomized and external evaluations, including of the malignancy alert, are needed.

来源:arXiv (AI + Vision + Imaging) · arxiv.org